Here you can find some of the most common problems and questions which can occur, together with our advices how to solve your problems. If you don't succeed to solve the problems yourself, you are always very welcome to contacts us with your questions about your ECCO equipment!
The pumps doesn’t start or doesn't work!
The air supply is blocked.
Too small diameter on the air hose.
The circulation- or paint pressure regulator is clogged or closed.
The filter, pipe or hose is clogged.
The pumps is working but is not pumping any fluid or is loosing pressure!
Wrong type of compressed air unit is used.
Dirt in the inlet or outlet valve.
The suction arrangement (pipe or hose) is leaking.
The packings in the pumps are worn out.
The paint flow from the pump is not stable!
Wrong type of compressor unit.
Leakage in the inlet and/or outlet valves.
The filter and/or hoses are clogged.
The painted surface has a "peel orange structure"!
Too low paint pressure.
Too high viscosity of the paint.
Wrong diameter and length of the paint hose give a pressure drop.
The spray tip is worn out.
The painted surface has stripes or cloudness!Too low paint pressure.
Too high viscosity of the paint.
Wrong diameter and length of the paint hose give a pressure drop.
The spray tip is worn out.
The painted surface has curtains!
Too low viscosity.
The spray tip is worn out.
Wrong angle of the gun or distance to the object.
A lot of paint dust!
Too high pressure on the atomization air
Too low paint viscosity.
Wrong distance between the gun and the object.
The solvent is too fast.
Pins in the paint!
The solvent is too fast.
Wrong type of pretreatment of the surface. |